s2d newbie here. This is a test environment, so nothing is probably supported hardware.
the setup
Running two optiplex 3050's with windows server 2016. They each have a spinning disk and an ssd via sata. the spinning disk is partitioned for the operating system and the rest i dumped into the s2d pool. With this hardware i setup a fail-over cluster w/ quarm coming from my domain controller, and the clusters' storage coming from the s2d pool. Everything was working well, but terrible slow.
the issue
To cure the slowness i decided to add a pcie, m.2 drive to each. After adding it to one machine the cluster and s2d drive came back w/ an error, i ran a repair inside of server manger. After that completed i added the same drive to the other machine and my s2d drive has been gone since. I've tried removing the last HD I added, rebooted each several times w/ no luck.
error's
when i look at the critical events for the cluster's disk in "fail-over cluster manager" there are a lot of repeating event ID. 5142, 1069, 1793
Any help would be greatly appreciated. I'd like to see if i can fix this in a test environment before i see it in production.
many thanks!
IT guy